Major Changes in Parts
- Convert all SMD to 805/603 (check power rating)
- Fix
Aluminum Capacitor Spacing by replacing with Tantulum (Alum. explodes
under too much pressure, therfore not suitable for underwater
applications
- Widen spacing between DB-9 and 4-40 hole, same with Power Trends Regulator PT6302A
- Change 0.1" header probe to fancy probes,
- Make Jumpers more modular, possibly use switches
- Don't Let the PT6302 hang off the dimensions
- Improve layout traces for higher currents
- Improve ground planes and spacing between components
- Fix Push button switch ease of use